BASIC POINTS IN CIVIL ENGINEERING

WhatsApp Image 2025 06 01 at 19.37.41 b045ddb1 BASIC POINTS IN CIVIL ENGINEERING

BASIC POINTS IN CIVIL ENGINEERING You Should Know,

Height of Residential Building3.1 m
Height of Window1.5 m
Height of Door2.1 m
Minimum diameter of bars used in the column1 m
Minimum height of Wall Construction in 1 day1.5 m
Density of Cement1440 kg/m³
Minimum Thickness of Slab125 mm (or) 5” Slab
Volume of Cement Bag1.25 CFT (or) 0.0347 m³
Number of Cement Bags in 1 m³28.8 bags
Lintel Thickness =150 mm
Lintel is Provided at2.1 m in case of a brick wall
DPC Thickness25 mm
Slope of Stairs25° – 40°
Min Rise150 mm
Min Tread230 mm
No. of Bricks in 1 m³550 Nos
Grade of Concrete for RCC SlabsM20
Free Fall of Concrete1.5 m
Compressive Strength of Brick is7.5 N/mm²
Standard Size of Brick19×9×9 (cm³)
Standard Size of Brick with Mortar20×10×10 (cm³)
No. of Bricks in 1 m³Minimum diameter of bars used in the column
Dimensional tolerance of a cube12 mm
Lapping should not be provided for36 mm diameter bars
Minimum diameter of bars used in the column36 mm dia bars
Max dia bars used in the slab12 mm
Lapping should not be provided for = 36 mm diameter bars1/8 × thickness of slab
Minimum diameter of bars used in the slab8 mm
Max dia bars in dowel bars12 mm
Max water absorption of first-class bricksMax water absorption of first-class bricks = 15% (dry weight)
Dimensional tolerance of cube± 2 mm
Initial setting time of cement30 mins
Final setting time of cement600 mins (10 hrs)
DPRDetailed Project Report
Unit weight of RCC= 25 kN/m³ (25000 N/m³)
Unit weight of PCC24 kN/m³ (24000 N/m³)
Steel unit weight7850 kg/m³
Weight of brick3.85 kg
Unit weight of sand (fine aggregate)→ 1600 (dry) kg/m³
→ 1840 (river) kg/m³
Unit weight of coarse aggregate (stone)3 feet (This seems to be a unit error; likely meant to be in kg/m³ or similar)
Mix GradesM5 = 1:5:10
M7.5 = 1:4:8
M10 = 1:3:6
M15 = 1:2:4
M20 = 1:1.5:3
M25 = 1:1:2
Cement strength checking at7 days, 14 days, 28 days
Cement Mortar Mixes2.1 m in the case of a brick wall
Interior plastering mixOrdinary masonry work = 1:3 to 1:6
Load bearing structure = 1:3 to 1:4
Reinforced brick work = 1:2 to 1:3
Moist situations = 1:3
(Cement: Sand)
Exterior plastering mix1:3
Flight Height1.5 m (or) the height of existing floor
Compressive strength is obtained at28 days

Also Read- How to Calculate Prestress Losses and Jacking Force in a Post-Tensioned Beamhttps://engineerlatest.com/how-to-calculate-prestress-losses-and-jacking-force-in-a-post-tensioned-beam/

1 comment