How to Calculate the Size of the footing
If,
Total Structure Load = 5000 KN
↓ (in Kg)
= 5000 × 101.97
1KN=101.97Kg1 KN = 101.97 Kg1KN=101.97Kg
= 509850 Kg
If, Bearing Capacity of Soils,
= 1800 Kg/m²
Total Structure Load Bearing Capacity = \frac{Total Structure Load}{Bearing Capacity}
= \frac{509850}{18000}
=28.325 m^2
Area of 1 footing ⇒
Area of 1 footing = \frac{Required Area for footing}{No. of Columns in building}
= \frac{28.325}{9}
=3.147 m^2
Sige of footing = \sqrt{3.1477m}
=1.77m X 1.77m
How to Calculate the Size of the footing
Related Articles: Foundation Guidelines and Depth Criteria | Footings and Foundations Explained
Design Disclaimer: This content is for educational reference. Actual structural design must be verified by a qualified engineer using project-specific data and the applicable current codes.